Flaw Detector | Fruit Hardness tester | Rockwell hardness tester | Force gauge | Thickness gauge |
Features:
1, using magnetic and eddy current two thickness method can measure the thickness of non-magnetic metal matrix magnetic coating can be measured non-magnetic metal matrix on the thickness of the non-conductive coating;
2, split (connection between the sensor and instrument by lead), dual (F-type N-type one)
3, the unique temperature compensation algorithm
4, with two measurements: continuous measurement mode (CONTINUE) and a single measurement (SINGLE);
5, Bluetooth wireless communications, voice broadcast reading
6, automatic probe recognition
7, support for thermal printing, instant report output
8, statistical functions: average value (Here MEAN), maximum value (the MAX), minimum value (the MIN), the number of tests (NO.), Standard deviation (S.DEV);
9, with storage function: can store 500 measurement values; values
Applications:
Widely used in metal processing, chemical, commodity inspection, electroplating, painting, pipeline corrosion, aluminum, steel and other industries, but also for shipbuilding, aerospace, power, pot special inspection, Technical Supervision and other industries.
Specifications::
Probe Type |
F |
N |
|
Working principle |
Magnetic induction |
vortex |
|
Measuring range |
0~1250μm |
0~1250μm【Chrome-plated copper(0~40μm)】 |
|
Resolution |
0.1μm(0~50μm ),1μm(>50μm ) |
||
Measurement error |
3%H+1μm(H measurement range)See Table a |
||
Indication error |
Point calibration(um) |
±(3%H+1) |
±(3%H+1.5) |
Two-point calibration(μm) |
±[(1~3)%H+1] |
±[(1~3)%H+1.5] |
|
Test Conditions |
min radius of curvature(mm) |
凸 1.5 |
凸3 |
diameter of the smallest area(mm) |
Φ7 |
Φ5 |
|
Minimum substrate thickness(mm) |
0.5 |
0.3 |
|
Operating Voltage |
2x3.7 V rechargeable lithium battery |
||
Dimensions |
198mm x 82mm x 30mm |
||
Instrument Weight |
320g |
Standard configuration:
name |
number |
name |
number |
Host computer |
1 |
printer |
1 |
Probe (F or N) |
1 |
Matrix (iron or aluminum) |
1 |
Standard test pieces |
5 |
1.5V alkaline batteries |
3 |
Instructions |
1 |
Warranty Card |
1 |
Certificate |
1 |
Packing List |
1 |
Optional probe parameters:
Probe Model |
F400 |
F1 |
F1/90 |
F10 |
N1 |
CN02 |
|
working principle |
Magnetic induction |
Electric Eddy currents |
|||||
Measuring range(μm) |
0-400 |
0-1250 |
0-10000 |
0-1250 |
10-200 |
||
Resolution(μm) |
0.1 |
0.1 |
10 |
0.1 |
1 |
||
Indication error |
Point calibration(μm) |
±(3%H+1) |
±(3%H+10) |
±(3%H+1.5) |
±(3%H+1) |
||
Two-point calibration (μm) |
±[(1-3)%H+0.7] |
±[(1-3)%H+1] |
±[(1-3)%H+10] |
±[(1-3)%H+1.5] |
— |
||
Test Conditions
|
min radius of curvature(mm) |
凸1 |
凸1.5 |
Straight |
10 |
3 |
Straight |
diameter of the smallest area(mm) |
Φ3 |
Φ7 |
Φ7 |
Φ40 |
Φ5 |
Φ7 |
|
Minimum substrate thickness(mm) |
0.2 |
0.5 |
0.5 |
2 |
0.3 |
Unlimited |
Force Gauge | Flaw Detector | Webster Hardness tester | Glossmeter | Fruit Hardness Tester | Thickness Gauge | Force Gauge | Hardness tester |